40kw-product.jpg

OCC-Bidirectional Converter

Breakthrough Technology

OCC-BDC leverages unique patented technology invented at Caltech & University of California and developed by the world-leading power electronic experts under partial sponsorship of the U.S. Department of Energy. OCC-BDC is the first hardware-enabled 3-phase Bidirectional Converter with high reliability, fast dynamics, and simple user interface, enabling autonomous bidirectional AC/DC conversion with regulated DC bus and unity power factor AC power.

 

Applications

  • Regenerative PFC front end for

    • motor drives

    • elevator AC/DC conversion

    • crane AC/DC conversion

  • Dynamically adjustable electronic load with energy recycling capability

  • Create DC a grid for

    • DC buildings

    • microgrid/hybrid grid/mobile grid

    • regenerative personal rapid transit systems

  • Power generation inverter for wind, micro-hydro, solar, etc.

  • Bidirectional inverter for flywheels, pumped-hydro energy, Rock power energy storage

 

Features

  • One-Cycle Control Technology

  • Power Factor > 0.99

  • Current harmonics < 3%

  • Efficiency > 98%

  • Stable zero load operation

  • Fast response speed (100s of microsec)

  • Lightweight ~ 30kg (70lbs)

  • High power density ~1.2W/cm3 (20W/inch3)

  • 400, 1000Hz, or variable frequency available for custom products

  • Single unit 40 or 60kW, scalable to MW

 

Specification

Product BDC3050A6480/8001IR BDC3050A5380/6351IR BDC3100A6208/3651IR
BDC3075A6480/8001IR BDC3075A5380/6351IR
Electrical Specifications
AC Phase/Wires 3 phase/3 wires
AC Freq Range (Hz) 57 - 63 47 - 53 57 - 63
AC Voltage Range (V, rms) Line-to-Line 400 - 552 320 - 440 175 - 240
Max AC Current (A, rms) 75 / 50 100
DC Bus Voltage (V) 800 635 365
Efficiency @ Full Power 98.3% / 97%
AC Current THD @ Full Power 3%
Power Factor @ Full Power 0.99
Mechanical Specification
Weight kg (lb) 32 (70)
Size (L x W x H) cm (inch) 58 x 45 x 13 (23 x 17.5 x 5.25)
Environment Specifications
Operating Temp. (℃) 0 to 40
Operating Relative Humidity w/o Condensation 0 - 95%
Storage Temp (℃) -10 to 55
Audible Noise (dBA) @ 1m (3ft) 80
Safety
UL 508C Designed