OCC-Bidirectional Converter
Breakthrough Technology
OCC-BDC leverages unique patented technology invented at Caltech & University of California and developed by the world-leading power electronic experts under partial sponsorship of the U.S. Department of Energy. OCC-BDC is the first hardware-enabled 3-phase Bidirectional Converter with high reliability, fast dynamics, and simple user interface, enabling autonomous bidirectional AC/DC conversion with regulated DC bus and unity power factor AC power.
Applications
Regenerative PFC front end for
motor drives
elevator AC/DC conversion
crane AC/DC conversion
Dynamically adjustable electronic load with energy recycling capability
Create DC a grid for
DC buildings
microgrid/hybrid grid/mobile grid
regenerative personal rapid transit systems
Power generation inverter for wind, micro-hydro, solar, etc.
Bidirectional inverter for flywheels, pumped-hydro energy, Rock power energy storage
Features
One-Cycle Control Technology
Power Factor > 0.99
Current harmonics < 3%
Efficiency > 98%
Stable zero load operation
Fast response speed (100s of microsec)
Lightweight ~ 30kg (70lbs)
High power density ~1.2W/cm3 (20W/inch3)
400, 1000Hz, or variable frequency available for custom products
Single unit 40 or 60kW, scalable to MW
Specification
Product | BDC3050A6480/8001IR | BDC3050A5380/6351IR | BDC3100A6208/3651IR |
---|---|---|---|
BDC3075A6480/8001IR | BDC3075A5380/6351IR | ||
Electrical Specifications | |||
AC Phase/Wires | 3 phase/3 wires | ||
AC Freq Range (Hz) | 57 - 63 | 47 - 53 | 57 - 63 |
AC Voltage Range (V, rms) Line-to-Line | 400 - 552 | 320 - 440 | 175 - 240 |
Max AC Current (A, rms) | 75 / 50 | 100 | |
DC Bus Voltage (V) | 800 | 635 | 365 |
Efficiency @ Full Power | 98.3% / 97% | ||
AC Current THD @ Full Power | 3% | ||
Power Factor @ Full Power | 0.99 | ||
Mechanical Specification | |||
Weight kg (lb) | 32 (70) | ||
Size (L x W x H) cm (inch) | 58 x 45 x 13 (23 x 17.5 x 5.25) | ||
Environment Specifications | |||
Operating Temp. (℃) | 0 to 40 | ||
Operating Relative Humidity w/o Condensation | 0 - 95% | ||
Storage Temp (℃) | -10 to 55 | ||
Audible Noise (dBA) @ 1m (3ft) | 80 | ||
Safety | |||
UL 508C | Designed |